BITMAIN ANTMINER S9-Hydro
Note: This batch ships out within 10 days upon receipt of payment. (first-order-first-paid.)
Note: Your order is only final after we confirmed it by sending the invoice.
Note: Order without VAT (0%) with a EU company VAT number or by ordering from outside EU
Note: The price of bitcoin mining machines must be adjusted frequently according to many factors, including Bitcoin/USD exchange rate, the network difficulty, and expected difficulty increase. Refund requests based on price changes cannot be honored.
Note: Up to two years warranty instead of 180 days.
Notifications
- Please click here for the installation guide. Suggested specifications for radiators, accessories and powersupplies that are not purchased from us can be found in the guide.
- The APW5 to power the Antminer S9-Hydro is included in your order.
- The waterpump for cooling is also included in your order.
- Please note the stated information if you cannot use a 220 V input for APW5.If you are using a 110 V input for APW5, the rated power is 1300 W and will not be capable to power the S9-Hydro.If you are using a 220 V input, the rated power will be 2600 W and will be able to power the S9-Hydro.
Antminer S9-Hydro Specifications
Product Glance | Value | ||
Product model | S9 Hydro-18.0T | ||
Hashrate, TH/s | 18.00 | ||
Power efficiency on wall @25°C, J/TH | 96.00 | ||
Adapted power supply model | APW5 | ||
Adapted power supply, Watt / Volt | 1728W / 220V | ||
Detailed Characteristics | Value | ||
Min | Typ | Max | |
Hashrate & Power | |||
Hashrate, TH/s | 18.00 | 18.40 | |
Power efficiency on wall @25°C, J/TH (1-1) | 96.0 | 102.7 | |
Power efficiency on wall @40°C, J/TH (1-2) | 103.2 | 110.4 | |
Power on wall, W (1-3) | 1728 | 2031 | |
Power Supply Input Range | |||
Power supply input voltage, V AC (2-1) | 200 | 220 | 265 |
Power Supply input Frequency Range, Hz (2-2) | 47 | 50 | 63 |
Power supply input current, A (2-3) | 7.85 | 10.16 | |
Power Supply Safety Protection | |||
Output Overcurrent Protection, A DC (3-1) | 216 | 225 | |
Low Voltage Input Protection, V AC | 90 | 100 | |
Hardware Configuration | |||
Quantity of hash chips | 216 | ||
Quantity of hash boards | 4 | ||
Networking connection mode | RJ45 ethernet 10/100M | ||
Miner Size (Length*Width*Height), mm(4-1) | 360*125*190 | ||
Net weight, kg (4-2) | 5.15 | ||
Noise, dBA @25°C (4-3) | 45 | 58 | |
Environment Requirements | |||
Water inlet temperature, °C | 15 (5-1) | 55 | |
Water flow, L/min | 5 (5-2) | 15 | |
Flow system pressure, kPa | 50 | 300 | |
Operation temperature, °C | 0 | 25 | 40 |
Storage temperature, °C | -40 | 25 | 85 |
Operation humidity, RH | 5% | 95% |
Specifications
(1-1) Miner test in 25°C temperature chamber. Heat exchanger and water pump power are included.
(1-2) Miner test in 40°C temperature chamber. Heat exchanger and water pump power are included.
(1-3) Typ condition: 25°C, min J/TH, typical Hashrate
Max condition: 40°C, max J/TH, max Hashrate
(2-1) Caution: Supply lower than 200V will cause APW5 protection or damage
Due to APW output power will be reduced by 50% under 200V input, and it is not enough for miner
(2-2) 220V AC Power Supply Frequency|
(2-3) Typ condition: Min Power on wall, 220V AC supply
Max condition: Max Power on wall, 180V AC supply
(3-1) During 220V AC input
(4-1) Without APW5 & Heat exchanger and water pump, including the bend pipes . APW5 L*W*H(mm) = 260*125*86
(4-2) Without APW5 & Heat exchanger, pump, including the bend pipes, APW5 net weight is 2.5kg
(4-3) Typ condition: 25°C, typical J/TH, typical Hashrate
Max condition: 40°C, max J/TH, max Hashrate
(5-1) Temperature should be no less than 15°C, and at least 3°C higher than dew point
(5-2) The external water source can appropriately reduce the flow according to the actual water temperature. Under this condition, the recommendation is no less than 2L/min.
Notes: The use of outdoor water sources (cooling towers, natural water sources) will cool the system more effectively than the Radiators & Accessories. The flow rate can be adjusted accordingly, but it is recommended to be no less than 2L/min. If the flow rate is too low, it will be greatly affected by the system resistance, which may lead to uneven branch flow.
Antminer S9-Hydro
Antminer S9-Hydro back
Antminer S9-Hydro top
Antminer S9-Hydro with PSU